Val Controls Delivers a HIPPS solution to ADNOC

Each HIPPS consist of two hydraulically actuated Shutdown valves, each one being controlled by two pressure pilots, all in a skid-mounted package. The valves arrangement is in series within the pipeline.

High-pressure detection function

If high-pressure is detected, the HIPPS closes the Shutdown valves and protect the downstream facility against elevated pressure.

The shutdown assembly

The shutdown Valves & Actuator Assembly features Partial stroke testing system – “Smart” type IDC24 from Val Controls.

Smart systems involve:

digital valve positioners
provides date and time stamp of tests
store and compare test results
remote testing and data retrieval.

End User: ADNOC ONSHORE
Project:  HIPPS SYSTEM For RUMAITHA THAMAMA ZONE B PHASE III EXPANSION DEVELOPMENT & CONVERSION OF RA PHASE I/II CO2 AFFECTED WELLS
Process Fluid: Multiphase Process Oil and Injection Gas
System Integrator: Sensia FZE, Jebel-Ali, Dubai
Val Controls unit: IDC24-AF, SS316L, Ex d/Ex e, HART communication

As End-user, FEED, EPC or OEM, let us help you optimize your valve control solutions and please feel free to contact us.